| Customization: | Available |
|---|---|
| Control Type: | PLC |
| Customized: | Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Picture:

| LPDC Machine Technology Specification | ||||
| Parameter | Unit | J452L | J455L | J458L |
| Machine body | ||||
| Fixed columns clearance | mm | 1050*750 | 1400*1000 | 1750*1250 |
| Distance between mobile and fixed platen | mm | 450-900 | 500-1350 | 550-1800 |
| Side cylinder stroke | mm | 250 | 300 | 450 |
| Opening force of the upper cylinder | KN | 122 | 177 | 245 |
| Closing force of the upper cylinder | KN | 94 | 138 | 305 |
| Opening force of side cylinder | KN | 59 | 94 | 165 |
| Closing force of side cylinder | KN | 78 | 122 | 212 |
| Ejection force | KN | 122 | 177 | 305 |
| Holding furnace | ||||
| Furnace type | crucible | crucible or refractory | ||
| Capacity | KG | 300 | 500 | 800 |
| Power rate | KW | 20 | 30 | 40 |
| Temperature control accuracy | ±ºC | 2 | 2-5 | |
| Furnace pressure | Bar | Max. 1.5 bar | ||
| Hydraulic pump station system | ||||
| Motor type (Regulation or Servo) | optional | |||
| Motor power rate | KW | 5.5 | 15 | 18.5 |
| Hydraulic pressure | Bar | Min. 80 bar -max. 120 bar | ||
| Pump type (gear or plunger) | Optional | |||
| Cooling type | Air | Air or water | Water | |
| Cooling water consumption | L/Min | 40 | 50 | |
| Operation control system | ||||
| PLC, HMI unit | Siemens | |||
| Operation method | Automatic | |||
| Main power voltage (380V 60HZ,400V 50HZ) | V, HZ | Optional | ||
| Auxiliary power voltage | V, HZ | 24 | ||
| Control cabinet cooling type | Fan | Fan or air conditioning | ||
